- Home
- ยป
- Our Product Range
- »
- ABB Electromechanical Relays
ABB Electromechanical Relays
1MYN742832-A IRXM ABB Make Restricted Earth Fault Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Application | Protection Panel |
| Coil Voltage | 110 V DC |
| Voltage | 24V DC |
| Contact Configuration | 2NO+1NC |
| Brand | ABB |
| Current (Amp) | 1A & 5A |
| Relay Type | Restricted Earth Fault Relay |
| Frequency | 50Hz |
| Country of Origin | Made in India |
| Mounting Type | Panel |
| Ordering Code | 1MYN742832-A |
1MYN742832-A, ABB Make IRXm, Circulating Current Relay, 1A & 5A, 24 V DC, 2N/O+1N/C, Flush mounting.
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN569697-A ABB Make TCS Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Product Series | TCS |
| Voltage | 24V DC |
| Coil Voltage | 24 V DC |
| Relay Type | Trip circuit supervision relay |
| Brand | ABB |
| Mounting Type | Panel |
| Usage/Application | Trip Circuit supervision |
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Contact Configuration | 1NO + 1NC + 2C/O |
| Ordering Code | 1MYN569697-A |
1MYN569697 - A, ABB Make TCS , Trip Circuit Supervision Relay, 1NO+1NC+2CO, Flush mounting.
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN563627-DBB ABB Make Transformer Protection Relay ( CV2D2J )
Minimum Order Quantity: 1 Piece
Product Brochure
| Function | Auxiliary |
| Number of Contacts | 4 NO |
| Coil Voltage | 110 V DC |
| Voltage | 110V DC |
| Brand | ABB |
| Relay Type | Transformer Protection Relay |
| Voltage Type | DC |
| Model Name/Number | CV2D2J |
| Type | Voltage Relays |
| Country of Origin | Made in India |
The ABB Type CV2D2J is an instantaneous hinged-armature relay designed for use in control and protective systems within industrial plants and power stations.
Here's a Key Features of Products:
- Primary Application: It is mainly used in HT VCB panels as transformer protection relay.
- Key Features:
- Small size.
- High degree of reliability, even after prolonged idle periods.
- Mechanical operation indicator.
- High contact rating.
- Available with 4 contacts with double interruption.
- Wide range of AC and DC voltage options.
- Low power consumption.
- Operation Indicator: When the relay picks up, an orange ring appears on an indicating knob, which can be reset by pressing it back in.
- Contact Configuration: The relay can have two contacts (either two normally open, or one normally open and one normally closed). Figures also show configurations for 4 contacts, such as 4NO+0NC, 2NO+2NC, and 3NO+1NC.
- Mounting Variants: Three main variants are available:
- Flush mounting case (1/2 ‘S’ size).
- Plug-in base mounting.
- Sheet-metal base mounting. Separate relays can also be supplied without a hood for incorporation into other equipment.
- Type Designations: The naming convention indicates voltage type (AC/DC), mounting style (e.g., H for single element without protective cover, RM for sheet-metal, RN for plug-in, J for 1/2‘S’ flush mounting). Examples of available types include CV2AJ, CV2DJ, CV2A2J, CV2D2J, CV2DRM, CV2RDN, CV2DH, CV2DM, CV2DN.
- Technical Data Highlights:
- Rated Voltage : 110V DC
- Operating Range: +10% to -20% of the Rated Voltage.
- Frequency: 50 Hz +/-5%.
- Pick-up Voltage: Less than 75% of Rated Voltage.
- Drop-off Voltage: Greater than 15% of Rated Voltage.
- Pick-up Time: 20-35 milliseconds.
- Maximum Power Consumption: 3W for DC; 2.5 VA for AC.
- Insulation Tests: Meets IEC 60255-5 standards for dielectric (2kV, 50Hz, 1 min), impulse voltage (5kV, 1.2/50 micro sec), and insulation resistance (>100 M ohms at 500V DC).
- Switching Rate: Up to 1000 operations/hour at full breaking current, or 3600 times/hour with reduced breaking current.
- Contacts: Rated voltage 250V DC/AC, rated current 10A, max. making current 30A. Max. Breaking capacities vary by voltage and load type.
- Environmental Tests: Withstands dry heat (+55°C and +70°C), dry cold (-10°C and -25°C), damp heat cyclic, and storage tests as per IEC standards.
- Vibration and EMC: Tested for vibration response and endurance (IEC 60255-21-1 Class-1) and high frequency disturbance (IEC 60255-22-1).
- Weight: Varies by type (e.g., Type N: 0.69 Kg, Type M: 0.68 Kg, Type 2J: 0.85 Kg).
- Manufacturer: Asea Brown Boveri Limited (ABB), Substation Automation Products, located in Maneja, Vadodara, India.
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN563627-ABB - ABB Make Transformer Protection Relay ( CV2D2J )
Minimum Order Quantity: 1 Piece
Product Brochure
| Function | Auxiliary |
| Voltage Level | 11 KV |
| Number of Contacts | 4 NO |
| Coil Voltage | 24 V DC |
| Voltage | 24V DC |
| Brand | ABB |
| Relay Type | Transformer Protection Relay |
| Voltage Type | DC |
| Model Name/Number | CV2D2J |
| Country of Origin | Made in India |
The ABB Type CV2D2J is an instantaneous hinged-armature relay designed for use in control and protective systems within industrial plants and power stations.
Here's a Key Features of Products:
- Primary Application: It is mainly used in HT VCB panels as transformer protection relay.
- Key Features:
- Small size.
- High degree of reliability, even after prolonged idle periods.
- Mechanical operation indicator.
- High contact rating.
- Available with 4 contacts with double interruption.
- Wide range of AC and DC voltage options.
- Low power consumption.
- Operation Indicator: When the relay picks up, an orange ring appears on an indicating knob, which can be reset by pressing it back in.
- Contact Configuration: The relay can have two contacts (either two normally open, or one normally open and one normally closed). Figures also show configurations for 4 contacts, such as 4NO+0NC, 2NO+2NC, and 3NO+1NC.
- Mounting Variants: Three main variants are available:
- Flush mounting case (1/2 ‘S’ size).
- Plug-in base mounting.
- Sheet-metal base mounting. Separate relays can also be supplied without a hood for incorporation into other equipment.
- Type Designations: The naming convention indicates voltage type (AC/DC), mounting style (e.g., H for single element without protective cover, RM for sheet-metal, RN for plug-in, J for 1/2‘S’ flush mounting). Examples of available types include CV2AJ, CV2DJ, CV2A2J, CV2D2J, CV2DRM, CV2RDN, CV2DH, CV2DM, CV2DN.
- Technical Data Highlights:
- Rated Voltage : 24V DC
- Operating Range: +10% to -20% of the Rated Voltage.
- Frequency: 50 Hz +/-5%.
- Pick-up Voltage: Less than 75% of Rated Voltage.
- Drop-off Voltage: Greater than 15% of Rated Voltage.
- Pick-up Time: 20-35 milliseconds.
- Maximum Power Consumption: 3W for DC; 2.5 VA for AC.
- Insulation Tests: Meets IEC 60255-5 standards for dielectric (2kV, 50Hz, 1 min), impulse voltage (5kV, 1.2/50 micro sec), and insulation resistance (>100 M ohms at 500V DC).
- Switching Rate: Up to 1000 operations/hour at full breaking current, or 3600 times/hour with reduced breaking current.
- Contacts: Rated voltage 250V DC/AC, rated current 10A, max. making current 30A. Max. Breaking capacities vary by voltage and load type.
- Environmental Tests: Withstands dry heat (+55°C and +70°C), dry cold (-10°C and -25°C), damp heat cyclic, and storage tests as per IEC standards.
- Vibration and EMC: Tested for vibration response and endurance (IEC 60255-21-1 Class-1) and high frequency disturbance (IEC 60255-22-1).
- Weight: Varies by type (e.g., Type N: 0.69 Kg, Type M: 0.68 Kg, Type 2J: 0.85 Kg).
- Manufacturer: Asea Brown Boveri Limited (ABB), Substation Automation Products, located in Maneja, Vadodara, India.
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN563627-DBC ABB Make Transformer Protection Relay (CV2D2J)
Minimum Order Quantity: 1 Piece
Product Brochure
| Function | Auxiliary |
| Relay Type | Auxilliary Relay |
| Number of Contacts | 4 NO |
| Coil Voltage | 220 V DC |
| Voltage | 220-250 V DC |
| Mounting Type | Panel |
| Brand | ABB |
| Type | Auxiliary Relay |
| Material | Mild Steel |
| Frequency | 50Hz |
| Country of Origin | Made in India |
The ABB Type CV2D2J is an instantaneous hinged-armature relay designed for use in control and protective systems within industrial plants and power stations.
Here's a Key Features of Products:
- Primary Application: It is mainly used in HT VCB panels as transformer protection relay.
- Key Features:
- Small size.
- High degree of reliability, even after prolonged idle periods.
- Mechanical operation indicator.
- High contact rating.
- Available with 4 contacts with double interruption.
- Wide range of AC and DC voltage options.
- Low power consumption.
- Operation Indicator: When the relay picks up, an orange ring appears on an indicating knob, which can be reset by pressing it back in.
- Contact Configuration: The relay can have two contacts (either two normally open, or one normally open and one normally closed). Figures also show configurations for 4 contacts, such as 4NO+0NC, 2NO+2NC, and 3NO+1NC.
- Mounting Variants: Three main variants are available:
- Flush mounting case (1/2 ‘S’ size).
- Plug-in base mounting.
- Sheet-metal base mounting. Separate relays can also be supplied without a hood for incorporation into other equipment.
- Type Designations: The naming convention indicates voltage type (AC/DC), mounting style (e.g., H for single element without protective cover, RM for sheet-metal, RN for plug-in, J for 1/2‘S’ flush mounting). Examples of available types include CV2AJ, CV2DJ, CV2A2J, CV2D2J, CV2DRM, CV2RDN, CV2DH, CV2DM, CV2DN.
- Technical Data Highlights:
- Rated Voltage : 220-250V DC
- Operating Range: +10% to -20% of the Rated Voltage.
- Frequency: 50 Hz +/-5%.
- Pick-up Voltage: Less than 75% of Rated Voltage.
- Drop-off Voltage: Greater than 15% of Rated Voltage.
- Pick-up Time: 20-35 milliseconds.
- Maximum Power Consumption: 3W for DC; 2.5 VA for AC.
- Insulation Tests: Meets IEC 60255-5 standards for dielectric (2kV, 50Hz, 1 min), impulse voltage (5kV, 1.2/50 micro sec), and insulation resistance (>100 M ohms at 500V DC).
- Switching Rate: Up to 1000 operations/hour at full breaking current, or 3600 times/hour with reduced breaking current.
- Contacts: Rated voltage 250V DC/AC, rated current 10A, max. making current 30A. Max. Breaking capacities vary by voltage and load type.
- Environmental Tests: Withstands dry heat (+55°C and +70°C), dry cold (-10°C and -25°C), damp heat cyclic, and storage tests as per IEC standards.
- Vibration and EMC: Tested for vibration response and endurance (IEC 60255-21-1 Class-1) and high frequency disturbance (IEC 60255-22-1).
- Weight: Varies by type (e.g., Type N: 0.69 Kg, Type M: 0.68 Kg, Type 2J: 0.85 Kg).
- Manufacturer: Asea Brown Boveri Limited (ABB), Substation Automation Products, located in Maneja, Vadodara, India.
Additional Information:
- Delivery Time: Ex-Stock (Immediate)
1MYN742832-E IRXM ABB Make Restricted Earth Fault Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Product Series | IRXM |
| Type | Restricted Earth Fault |
| Coil Voltage | 110-125V DC |
| Brand | ABB |
| Voltage | 110V DC |
| Usage/Application | Master Trip |
| Current | 1A & 5A |
| Country of Origin | Made in India |
| Relay Type | Restricted Earth Fault |
| Mounting Type | Panel |
| Frequency | 50Hz |
| Ordering Code | 1MYN742832-E |
Additional Information:
- Delivery Time: Subject to Stock Availability
ABB Make VHXM22A -1MYN742637-DAF
Minimum Order Quantity: 1 Piece
Product Brochure
| Coil Voltage | 110VAC, 110VDC |
| Contact Configuration | 3NO+3NC |
| Application | Under Voltage Relay without Time Delay |
| Usage/Application | Control Panel |
| Type | Undervoltage relay |
| Voltage Type | AC |
| Voltage (V) | 110VAC, 110VDC |
| Brand | ABB |
| Country of Origin | Made in India |
| Material | Mild Steel |
1MYN742637-DAF VHXM22A, Under Voltage Relay w/o Timer, 110VAC, 110VDC, 3NO+3NC,4080%, Flush mounting
ABB Make VHXM23A - 1MYN742640-DAF
Minimum Order Quantity: 1 Piece
Product Brochure
| Coil Voltage | 110VAC, 110VDC |
| Application | Over Voltage Relay without Time Delay |
| Contact Configuration | 3NO+3NC |
| Usage/Application | Control Panel |
| Type | Overvoltage Relay |
| Voltage Type | AC |
| Voltage (V) | 110VAC,110VDC |
| Country of Origin | Made in India |
| Material | Mild Steel |
1MYN742640-DAF VHXM23A, Over Voltage Relay w/o Timer, 110VAC,110VDC, 3NO+3NC, 80140%, Flush mounting
Additional Information:
- Delivery Time: 2-3 weeks
ABB Make VHXM22B - 1MYN742631-DAF
Minimum Order Quantity: 1 Piece
Product Brochure
| Coil Voltage | 110VAC, 110VDC |
| Contact Configuration | 3NO+3NC |
| Application | Under voltage relay with variable time delay |
| Usage/Application | Control Panel |
| Type | Undervoltage relay |
| Voltage | AC / DC |
| Voltage Type | AC |
| Voltage (V) | 63.5/110/240 V AC,40-80%,0.1-1.0 sec/0.5-5.0 sec/1-10 sec,24/30/48/110/220 V DC |
| Model Name/Number | VHXM |
| Coil Type | Latching |
| Brand | ABB |
| Number Of Poles | 2 Pole |
| Country of Origin | Made in India |
| Material | Mild Steel |
VHXM22B, Under Voltage Relay with Timer, 110VAC, 110VDC,3NO+3NC, 4080%, 0.5-5.0 Sec, Flush mounting
1MYN742844-D UVT92M ABB Make Fuse Failure Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Type | Fuse Failure |
| Voltage | 110V AC, 110V DC |
| Relay Type | Fuse Failure |
| Mounting Type | Panel |
| Brand | ABB |
| Model Name/Number | UVT92M |
| Usage/Application | Fuse Failure Relay |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Ordering Code | 1MYN742844-D |
1MYN742844-D, UVT92M ABB Make Fuse Failure Relay, 110VAC, 50 Hz, 110VDC, 2CO, Flush mounting.
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN569697-G ABB Make TCS Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Voltage | 220-250V DC/AC |
| Brand | ABB |
| Usage/Application | Trip Circuit supervision |
| Country of Origin | Made in India |
| Mounting Type | Panel |
| Frequency | 50Hz |
| Ordering Code | 1MYN569697-G |
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN569697-E ABB Make TCS Relay
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | ABB |
| Voltage | 110-125V AC/DC |
| Usage/Application | Trip Circuit supervision |
| Country of Origin | Made in India |
| Mounting Type | Panel |
| Frequency | 50Hz |
| Ordering Code | 1MYN569697-E |
Additional Information:
- Delivery Time: Subject to Stock Availability
1MYN563612-DAD ABB Make PN8nCH2j ( DC Supervision/ Fail) Relay
Product Brochure
| Brand | ABB |
| Relay Type | Supervision |
| Mounting Type | Flush Mounting |
| Voltage | 24/30/48/110/220 V DC,110/240 V AC |
| Type | Industrial Relay |
| Model Name/Number | PN8nCh2J |
| Frequency | 50 Hz |
| Ordering Code | 1MYN563612-DAD |
Additional Information:
- Delivery Time: 2 - 3 Weeks